An X-ray machine has a tube that makes the beam, the patient, and a receiver that records the X-rays that pass through. The FDA describes radiography as generating and recording an X-ray pattern to give a static image after the exposure ends. During the procedure the beam passes through the body, a portion of the X-rays is absorbed or scattered by the internal structure, and the rest of the pattern reaches a detector so an image can be recorded for later evaluation. RadiologyInfo.org adds that radiation passes through bones, tissues and organs differently, which is what lets a radiologist create images of them.

Four boxes in a row: X-ray tube, patient, receiver, image.
How an X-ray image forms. Original IOI diagram.

What makes the beam

The tube accelerates electrons by an electrical voltage and stops them in a target. Radiopaedia gives the potential difference as between 30 and 150 kV. Almost all of the electrons' energy becomes heat, about 99 per cent, and about 1 per cent becomes X-rays. How an X-ray tube works covers this in detail.

A spectrum, not one colour

The FDA's compliance manual says X-ray machines produce a continuous spectrum of X-rays, with energies from near zero up to a maximum set by the selected tube potential. The largest number of X-rays occurs at an energy much lower than the maximum, and a good estimate of the effective energy of the beam is about one third of the maximum.

Why voltage changes the picture

When a radiographer looks at the image, the FDA explains, they see the contrast between body constituents such as bone and muscle. That contrast varies greatly with the X-ray energy. At one energy the contrast between two soft tissues is at its greatest, and at another it is far less. The same is true for bone, muscle, fluid and air-filled organs. The diagnostic information needed decides the energy used. The FDA also requires enough filtration in the beam to give an appropriate half-value layer for the operating kVp.

Recording the image: film or electronics

The FDA says the pattern may be recorded on film or by electronic means. Radiopaedia describes the digital side: digital radiography captures and stores the radiograph as discrete digital values rather than the continuous values of film, and removes the need for darkroom procedures. It names two families. Computed radiography uses photostimulable phosphor plates in cassettes. Direct digital radiography registers the image directly in a flat-panel detector. In a flat panel, direct conversion registers X-rays straight away, while indirect conversion first turns them into visible light with a scintillator and then registers that light.

One machine, several procedures

The FDA separates radiography from fluoroscopy, mammography and computed tomography, which it treats as other procedures. Radiography is used where a record of a static image is wanted, for example a spot film during fluoroscopy. RadiologyInfo.org notes that X-rays also help place tubes and other devices in the body, and can treat disease. The dose varies by procedure, and the FDA says radiography is generally lower than fluoroscopy and computed tomography; see how much radiation is in an X-ray.

Where it began

Röntgen's own account of what the rays penetrate is in the history of the X-ray machine. During World War 1 the machine moved into vehicles; see X-ray mobile units in World War 1.

Quick answers

How does an X-ray machine work?

A tube makes an X-ray beam, the beam passes through the body where some is absorbed, and a receiver records the X-rays that get through as a shadow image.

Why do bones show up on X-rays?

Bones absorb more of the beam than soft tissue, so fewer X-rays reach the receiver behind them. The difference forms the image.

What voltage does an X-ray tube use?

Radiopaedia gives the range as 30 to 150 kV. The choice depends on what is being imaged.

Sources

Image formation, film or electronic recording and the comparison with other procedures are from the FDA radiography page. Absorption by different tissues is from RadiologyInfo.org. Voltage range and the 99 per cent heat figure are from Radiopaedia. The spectrum, contrast and filtration statements are from the FDA compliance manual. Detector types are from the Radiopaedia digital radiography article. Machine designs vary; this describes general radiography, not fluoroscopy, mammography or CT.

More from this book

History · From the book The X-ray Machine

The history of the X-ray machine: Röntgen's discovery in 1895

X-rays were found by accident, by a physicist studying something else.

Explainer · From the book The X-ray Machine

How an X-ray tube works, from Coolidge to today

Most conventional medical X-ray systems rest on one device: an evacuated tube, usually glass but sometimes with a metal envelope, where electrons are boiled off a filament, accelerated and stopped at a target.

History · From the book The X-ray Machine

X-ray mobile units in World War 1: Marie Curie's petites Curies

In 1914 X-ray machines were in hospitals, not at the front.

Explainer · From the book The X-ray Machine

How much radiation is in an X-ray? Doses compared

The radiation in an X-ray is real but small, and it is measured against the radiation everyone gets from the ground, the air and space.