Cover of The Natural Gas Pipeline: Steel, Pressure, Flow, a book by Ketineni RamaraoFrom the book The Natural Gas Pipeline: Steel, Pressure, Flow
Chapters 8 to 10. Read the full book free as a PDF.

Why the pipe runs at high pressure

High pressure is less about pushing harder than about making each metre of pipe carry more. The book adds that gas does not follow the ideal gas law exactly: at transmission pressures a correction factor, usually written Z, falls below 1, so the pipe holds more gas than the simple law predicts.

What friction does

As gas flows, friction against the pipe wall drains its pressure. The pressure falls slowly at first and then faster, because the gas expands and speeds up as the pressure drops. Without help the pressure would eventually be too low to keep the gas moving at the planned rate. The fix is a compressor station, which takes gas at the pressure left after friction, raises it, and sends it on. Plotted along the line, the pressure looks like the teeth of a saw: down along a stretch of pipe, up at a station.

Line chart: pressure falls along each stretch of pipe from about 100 bar to 70 bar and jumps back at each compressor station.
Pressure along a pipeline. Illustrative, computed by IOI; not a real line.

INGAA, the US interstate pipeline trade association, says compressor stations are above-ground facilities generally every 40 to 100 miles along a pipeline, using natural gas or electricity to power the compressors. Penn State Extension describes what happens inside: gas passes through scrubbers and filters to remove liquids and solids, goes to the compressors, and computers regulate how many units run to match the flow.

What sets a pipe's capacity

The book uses the Weymouth relationship, an engineering formula, to show how capacity responds to design. In words, flow rises with the diameter to the power of eight-thirds, rises with the square root of the difference between the squares of the inlet and outlet pressures, and falls with the square root of the length. Working from those exponents gives three results. They come from the simplified formula, which assumes steady, isothermal flow of one gas and an empirical friction factor that depends on pipe diameter (it is not a constant Darcy friction factor), so treat them as a guide to scaling, not as a design rule for any real line.

Bar chart: doubling pipe diameter raises capacity 6.3 times, doubling pressure at both ends raises it 2 times, and doubling length cuts it to 0.71 times.
How capacity scales, from the Weymouth relationship. Computed by IOI.

These are scaling results for an otherwise unchanged pipe, computed from the relationship the book cites. They are not a design method, and real lines also depend on temperature, gas composition and elevation.

What compression costs

Moving gas uses gas. A 2014 Journal of Petroleum Technology paper by T. M. Elshiekh puts compressor fuel use at 3 to 5 percent of the gas transported through a pipeline system, a system-wide figure rather than a rule for every station, and shippers pay for this in the tariff. INGAA lists the three usual drivers: a gas turbine with a centrifugal compressor, a reciprocating engine with a reciprocating compressor, and an electric motor, which burns no fuel at the station but needs a very reliable power supply nearby. The book describes the central design trade: a larger pipe costs more steel and burns less fuel for ever after, while a smaller pipe saves capital and pays in fuel. The right choice depends on the price of steel against the price of gas, the length and the expected flow.

The pipe is also a tank

The book describes linepack, the gas held inside the pipe itself. Because demand changes through the day and with the weather, a pipeline can absorb a surplus or cover a shortfall for a few hours by letting pressure rise or fall within its permitted range. For longer imbalances, the book says, the usual answer is underground storage in depleted gas fields, aquifers and salt caverns, which it describes as filling in summer and emptying in winter. For what happens when a pipe fails, see what four pipeline failures taught regulators.

Quick answers

Why do gas pipelines need compressor stations?

Friction with the pipe wall drains pressure as gas flows. A compressor station raises the pressure again so the gas keeps moving. INGAA says stations are generally 40 to 100 miles apart.

How much gas does a compressor station use?

A 2014 Journal of Petroleum Technology paper puts compressor fuel use at 3 to 5 percent of the gas transported through a pipeline system, when gas-powered; it is not a per-station default. Electric drives burn none at the station.

What matters more for capacity, diameter or length?

Diameter. In the Weymouth relationship, flow rises with diameter to the power 8/3 and falls only with the square root of length, so doubling diameter gives about 6.3 times the capacity.

Sources

Station spacing (40 to 100 miles) and power options are from INGAA. The station layout (scrubbers, filters, control) is from Penn State Extension. The 6.3, 2 and 0.71 results are computed by IOI from the exponents and are scaling ratios only. The sawtooth chart is illustrative, computed from the squared-pressure form, not data from a real line.

More from this book

Safety · From the book The Natural Gas Pipeline: Steel, Pressure, Flow

Why natural gas smells: the New London school explosion of 1937

Natural gas is nearly odourless.

Inspection · From the book The Natural Gas Pipeline: Steel, Pressure, Flow

What is a pipeline pig? How operators inspect a gas pipe from inside

You cannot dig up a thousand kilometres of pipe to look at it.

Safety · From the book The Natural Gas Pipeline: Steel, Pressure, Flow

Gas pipeline explosions: what San Bruno, Carlsbad and Natchitoches taught regulators

A pipeline failure releases a great deal at once.

Trade · From the book The Natural Gas Pipeline: Steel, Pressure, Flow

Pipeline or LNG ship? How natural gas gets to market

A pipeline is fixed and a tanker is not.