Engineering · Utilities · Gas Utilities
Why gas pipelines need compressor stations: pressure, friction and the sawtooth
A gas pipeline does not push gas the way a pump pushes water. It moves gas by letting pressure fall along the pipe, and it needs a compressor station every so often to lift the pressure again.
From the book The Natural Gas Pipeline: Steel, Pressure, FlowChapters 8 to 10. Read the full book free as a PDF.
Why the pipe runs at high pressure
High pressure is less about pushing harder than about making each metre of pipe carry more. The book adds that gas does not follow the ideal gas law exactly: at transmission pressures a correction factor, usually written Z, falls below 1, so the pipe holds more gas than the simple law predicts.
What friction does
As gas flows, friction against the pipe wall drains its pressure. The pressure falls slowly at first and then faster, because the gas expands and speeds up as the pressure drops. Without help the pressure would eventually be too low to keep the gas moving at the planned rate. The fix is a compressor station, which takes gas at the pressure left after friction, raises it, and sends it on. Plotted along the line, the pressure looks like the teeth of a saw: down along a stretch of pipe, up at a station.
INGAA, the US interstate pipeline trade association, says compressor stations are above-ground facilities generally every 40 to 100 miles along a pipeline, using natural gas or electricity to power the compressors. Penn State Extension describes what happens inside: gas passes through scrubbers and filters to remove liquids and solids, goes to the compressors, and computers regulate how many units run to match the flow.
What sets a pipe's capacity
The book uses the Weymouth relationship, an engineering formula, to show how capacity responds to design. In words, flow rises with the diameter to the power of eight-thirds, rises with the square root of the difference between the squares of the inlet and outlet pressures, and falls with the square root of the length. Working from those exponents gives three results. They come from the simplified formula, which assumes steady, isothermal flow of one gas and an empirical friction factor that depends on pipe diameter (it is not a constant Darcy friction factor), so treat them as a guide to scaling, not as a design rule for any real line.
- Diameter. Doubling it multiplies capacity by 2 to the power 8/3, about 6.3 times. Twice the diameter needs about twice the steel for the same wall, which is why trunk lines are large.
- Pressure. Doubling the pressure at both ends doubles the capacity, so pressure is a second route to more flow, limited by the steel and the rules.
- Length. Doubling the length cuts capacity to about 0.71 of the original, a loss of about 29 percent, not half. A long line can still carry a lot if pressure is restored on the way.
These are scaling results for an otherwise unchanged pipe, computed from the relationship the book cites. They are not a design method, and real lines also depend on temperature, gas composition and elevation.
What compression costs
Moving gas uses gas. A 2014 Journal of Petroleum Technology paper by T. M. Elshiekh puts compressor fuel use at 3 to 5 percent of the gas transported through a pipeline system, a system-wide figure rather than a rule for every station, and shippers pay for this in the tariff. INGAA lists the three usual drivers: a gas turbine with a centrifugal compressor, a reciprocating engine with a reciprocating compressor, and an electric motor, which burns no fuel at the station but needs a very reliable power supply nearby. The book describes the central design trade: a larger pipe costs more steel and burns less fuel for ever after, while a smaller pipe saves capital and pays in fuel. The right choice depends on the price of steel against the price of gas, the length and the expected flow.
The pipe is also a tank
The book describes linepack, the gas held inside the pipe itself. Because demand changes through the day and with the weather, a pipeline can absorb a surplus or cover a shortfall for a few hours by letting pressure rise or fall within its permitted range. For longer imbalances, the book says, the usual answer is underground storage in depleted gas fields, aquifers and salt caverns, which it describes as filling in summer and emptying in winter. For what happens when a pipe fails, see what four pipeline failures taught regulators.
Quick answers
Why do gas pipelines need compressor stations?
Friction with the pipe wall drains pressure as gas flows. A compressor station raises the pressure again so the gas keeps moving. INGAA says stations are generally 40 to 100 miles apart.
How much gas does a compressor station use?
A 2014 Journal of Petroleum Technology paper puts compressor fuel use at 3 to 5 percent of the gas transported through a pipeline system, when gas-powered; it is not a per-station default. Electric drives burn none at the station.
What matters more for capacity, diameter or length?
Diameter. In the Weymouth relationship, flow rises with diameter to the power 8/3 and falls only with the square root of length, so doubling diameter gives about 6.3 times the capacity.