Mechanism · Consumer Discretionary · Household Durables
How air conditioners work
Most modern room air conditioners, and the large chillers descended from Carrier's machines, run the same vapour-compression loop: a fluid is squeezed, cooled into liquid, relaxed through a restriction, and boiled back into vapour. The boiling steals heat from the room. The squeezing dumps it outside.
From the book The Air Conditioner: Ice, Vapor, EmpireChapter 11. Read the full book free as a PDF.
The loop and its four organs
Strip a typical vapour-compression air conditioner and four parts remain. The compressor draws in cool, low-pressure refrigerant vapour and squeezes it hot: this is the work input, the electricity bill. The condenser, the outdoor coil, lets that hot vapour give its heat to the outside air and collapse into liquid. The expansion valve, a calibrated restriction, drops the liquid's pressure and flashes it cold. And the evaporator, the indoor coil, is where the cold, low-pressure liquid boils back into vapour, pulling the heat of boiling out of the room's air. Then the vapour returns to the compressor and the loop repeats.
Cooling is export, not destruction
The physics worth keeping is that an air conditioner does not make cold. It moves heat. Heat will not flow uphill from a cool room to a hot afternoon by itself, so the compressor lifts it there, paying in electricity for the climb. That is why an air conditioner cannot cool a sealed room with its own exhaust inside it, and why the outdoor unit blows warm: that warmth is your room, shipped outside.
The refrigerant is a bloodstream, not a fuel
The fluid in the loop is chosen for its boiling point: low enough to boil in the indoor coil, tame enough to condense in the outdoor one. It circulates sealed, changing state but never being consumed. A healthy air conditioner therefore never needs a refill; a refill is a confession that something is leaking. What the refrigerant has been, chemically, is its own story, told in how air conditioning refrigerants changed.
Cold air is also dry air
The machine conditions, it does not merely chill. Warm air holds more water than cool air, so when room air crosses the cold evaporator coil, moisture condenses on the fins and drips away through the drain. That dehumidifying was the original point: Willis Carrier's 1902 system for a Brooklyn printer was built to control humidity, not temperature, because damp paper swelled between colour passes and ruined the register. The U.S. Department of Energy's history records that his "Apparatus for Treating Air" could humidify or dehumidify on demand. Comfort cooling of people came later; manufacturing came first.

Measuring cold: the ton
The trade still sizes machines in tons of refrigeration, a fossil of the ice trade the machines killed. ASHRAE's terminology defines one ton of refrigeration as 12,000 British thermal units per hour, about 3.52 kilowatts: the cooling power needed to melt one short ton of ice in a day. A bedroom unit runs about one ton; a house system three to five; a skyscraper's centrifugal chillers, the descendants of Carrier's 1922 centrifugal chiller, run into the thousands.
The same loop, run backwards
Nothing in the loop cares which side is indoors. Reverse the refrigerant's direction with a valve and the machine imports heat instead of exporting it: the outdoor coil boils refrigerant in the cold air, the indoor coil condenses it warm. That is a heat pump, and it is the same hardware with the flows swapped, which is why a modern split can heat a room for roughly a third of the electricity a resistance heater burns. The tonnage, the coils and the compressor are unchanged; only the direction of the climb reverses.
Why size matters
A right-sized machine runs in long, steady cycles. An oversized one slams the room cold in minutes, stops, restarts, and stops again, a pattern called short-cycling that wears the compressor and, worse, never runs long enough to condense much water off the coil, so the room ends up cold and clammy. The comfortable machine is the boring one: matched to the room, humming along, drinking little.
The other way to cool: water
There is a second, older route to cold air that uses no refrigerant at all. Evaporate water into dry air and the air's temperature falls with its dryness, the same physics that cools skin after a swim. Evaporative coolers work beautifully in a desert and not at all in a monsoon, which is why the refrigerant loop, which works across a far wider range of humidity than evaporative cooling, owns most of the world. The full family tree is in the types of air conditioning.
Where the electricity goes
In vapour-compression equipment the compressor is the main work input, though fans and controls also use electricity; the climb uphill for heat is the expensive part. That is why efficiency work concentrates on better compressors, bigger coils, variable-speed drives and smarter control, and why the same room can be held at the same temperature for very different amounts of electricity. The energy question has its own article: air conditioning's electricity demand.
Quick answers
Does an air conditioner bring in fresh air?
Not in a typical room or split air conditioner. It recirculates the room's own air through a cold coil and dumps the heat outside, with the heat carried through the wall by the refrigerant loop. Ventilated and portable designs can differ.
Why does an air conditioner drip water?
Room air loses moisture when it crosses the cold indoor coil, because cold air can hold less water vapour. The condensate collects and drains away: it is the room's humidity, removed.
What is a ton of air conditioning?
One ton of refrigeration is 12,000 BTU per hour, about 3.52 kilowatts, the power needed to melt a short ton of ice in 24 hours. The unit survives from the ice trade that mechanical cooling replaced.